1. TURN LOCK NUT APPROXIMATELY 1/8 IN FROM SENSOR FLANGE HEAD.
2. SCREW IN SENSOR UNTIL LOCK NUT BOTTOMS OUT AGAINST TRANSMISSION HOUSING.
3. ALIGN INDEXING MARK SO THAT THE MARK FACES THE GEAR TEETH.
4. LOCK SENSOR IN PLACE BY HOLDING THE FLANGE HEAD AND TIGHTENING THE LOCK NUT AGAINST THE TRANSMISSION HOUSING.
5. IF OPERATION IS NOT ACHIEVED, LOOSEN LOCK NUT AND TURN SENSOR FLANGE HEAD IN ONE COMPLETE TUN AND LOCK.
NOTE: ORIENTATION OF SENSOR TO GEAR IS IMPORTANT. MISALIGNMENT OF 15 DEGREES IN EITHER DIRECTION MAY AFFECT OPERATION.

OUTPUT SIGNAL 1: Serial Incremental
OUTPUT SIGNAL 2: Serial Incremental
OUTPUT SIGNALS: Independantly Buffered
OUTPUT IMPEDANCE: Approx 5k
SIGNAL DUTY CYCLE: Sensed Tooth Dependant Approx 50% Schmidt
Triggered
CURRENT SOURCE CAPACITY: 15 Ma. Max
OUTPUT SIGNAL FREQUENCY: 0 - 100 KHZ
GAP: .045 - .060 (Mass Dependant)
MAX RESOLUTION: .075 In.
SUPPLY VOLTAGE: 6.2V - 38V DC
OUTPUT SIGNAL VOLTAGE: 0 - Supply Minus 1.4V Peak To Peak
CABLE: 20 Ga. 4 Wire PVC Jacket Foil Shielded Floating
OUTPUT TERMINATION Customer Specified
OPERATING TEMPERATURE: -20 Deg C To +80 Deg C With PVC Jacketed Cable
-40 Deg C To +150 Deg C With Teflon Cable
CHEMICAL TOLERANCE: Impervios To Salt, Water, Oil & Transmission Fluid
MECHANICAL SHOCK: 30G Static And Dynamic (1k)

and are not allowed to be used on any other site.